Return to site

Iu22 User Manual

broken image


Download PHILIPS IU22 User Manual - PDF The Philips iU22 not only offers six different PureWave single crystal transducers, but five xMatrix probes. XMatrix not only improves image quality and penetration like a PureWave transucer, but also allows for real-time scanning of multiple planes and 4D without needing a typical mechanical 4D probe. The Philips iU22 is a premium shared service ultrasound machine that offers the best image quality possible through xMatrix transducers that offer the best aspects of single-crystal and 4D transducers. The iU22 offers the top of the line image quality and features available for Radiology, OB/GYN, Cardiac, Vascular and even specialty imaging like MSK, Pediatric, and Elastography. Model: iU22: Date: 2010: Category: Medical and Biomedical Equipment: Group: Ultrasound Equipment: Description: Information: The iU22 and iE33 ultrasound systems are general-purpose, mobile, software-controlled, diagnostic ultrasound systems for general imaging and cardiology and vascular applications. For the applications available with each system, see 'iU22 Applications' on page 73. The iU22 ultrasound system gives you exceptional image quality, ease of use, automatic quantification, and throughput to help you address the challenges you face in your vascular lab.

Philips iU22 Ultrasound System

Marti Rae

What's not to like about the iU22? It does so much and the cost has come down under $50,000. The iU22 system has superb image quality for all patient types, power proceesing, LCD, and advanced volume imaging solutions, innovative workflow tools and exceptional scanning ease.

Unique Philips iU22 xMATRIX technology on the X6-1 PureWave transducer delivers crisp, high-resolution images of even technically challenging patients. Exceptional 2D and 3D image quality from a single transducer. The new X6-1 PureWave xMATRIX transducer delivers outstanding 2D images, and then, with the touch of a button, converts to 3D to provide a more complete picture of anatomy without workflow disruption.
One of the top rated General Imaging Ultrasound Machines on the market.

17″ LCD (earlier models), 20″ LCD Monitor
SonoCT Compound Imaging (option)
xStream
XRES
iSCAN
M-mode
Live xPlane imaging
Color Power Angio imaging (CPA) and Directional CPA
PW Doppler
High-PRF PW Doppler
Duplex
Panoramic imaging
Spatio-temporal image correlation (STIC)
DVE
Options:
CW Doppler
DICOM
Realtime 3D/4D
Live 3D Echo
iCommand
Stress Echo
QLAB
Quicksave
iFocus

PureWave Crystal Technology
• Available on the S5-1, C5-1 and X7-2 transducers
• Breakthrough crystal technology allows greater acoustic efficiency and bandwidth

Want the latest upgrade – call us today.
Philips iU22 xMATRIX. Philips Vision 2012 upgrade revolutionizes ultrasound imaging.

L17-5 Linear
L12-5 50 mm Linear
VL13-5 Linear
L9-3 Linear
C5-1 Convex
C5-2 Convex
C8-5 MicroConvex
C9-4 Micrconvex
S5-1 Sector
S4-1 Sector
V6-2 3D/4D Convex
C9-5ec Endocavity
C8-4v Transvaginal,
3D9-3v 3D Transvaginal
X7-2 TEE
X3-1 Sector
x6-1 Matrix Sector
S7-2omni TEE
D2cwc
D2tcd
D5cwc

Iu22 Ultrasound Machine User Manual

Abdomen
Breast
Small Parts
Superficial
Pediatric
MSK
Obstetrics
Gynecology
Prostate
Vascular
TCD
Cardiac
Contrast Imaging
ICE

DESCRIPTION PART NUMBER
Dual Signal Conditioning 453561150491
Dual Signal Conditioning 453561150492
Dual Signal Conditioning 453561150493
Dual Signal Conditioning 453561150495
Front End Controller 453561150891
Front End Controller 453561150892
Front End Controller 453561150893
Front End Controller 453561150894
Front End Controller 453561150895
Front End Controller 453561150897
Front End Controller 453561150898
Front End Controller 453561153751
Front End Controller 453561153752
Acquisition Frontplane 453561153881
Acquisition Frontplane 453561153882
Acquisition Frontplane 453561153883
Acquisition Frontplane 453561153884
Acquisition Frontplane 453561153885
Acquisition Frontplane 453561153886
Acquisition Frontplane 453561153887
Acquisition Frontplane 453561153889
Scanhead Select 453561154401
Scanhead Select 453561154403
Channel Board 453561156011
Channel Board 453561156012
Channel Board 453561156013
Channel Board 453561156014
Channel Board 453561156016
Channel Board 453561156017
3D Motor Controller Board 453561157121
3D Motor Controller Board 453561157122
3D Motor Controller Board 453561157123
FEC w/ 3D Motor Controller 453561157131
FEC w/ 3D Motor Controller 453561157132
FEC w/ 3D Motor Controller 453561157133
Analog Input Module (AIM) 453561160671
Analog Input Module (AIM) 453561160672
Analog Input Module (AIM) 453561160673
Analog Input Module (AIM) 453561160674
Analog Input Module (AIM) 453561160675
Analog Input Module (AIM) 453561160676
Channel Board 453561164271
Dual Signal Conditioning 453561167371
Dual Signal Conditioning 453561167372
Rear Interface Panel (AVIO) 453561167391
Rear Interface Panel (AVIO) 453561167392
Scanhead Select 453561167791
Scanhead Select 453561167792
Control & Display (AVIO) 453561168091
Control & Display (AVIO) 453561168092
Neo Analog Interface Module (NAIM) 453561169242
Neo Analog Interface Module (NAIM) 453561169243
Neo Analog Interface Module (NAIM) 453561169244
SPD 453561170965
Acquisition Power Distribution 453561172773
Rear Interface Panel (AVIO) 453561185612
Scanhead Select 453561189671
Acquistion Card Cage 453561192762
Rear Interface Panel (AVIO) 453561200191
Image Export Processor (IEP) 453561202061
Image Export Processor (IEP) 453561202062
Acquistion Frontplane (AFP) 453561208341
Acquistion Frontplane (AFP) 453561208342
Acquistion Frontplane (AFP) 453561208343
Neo Analog Interface Module (NAIM)453561210221
Neo Analog Interface Module (NAIM) 453561210222
Neo Analog Interface Module (NAIM) 453561210223
Neo Analog Interface Module (NAIM) 453561210224
Neo Analog Interface Module (NAIM) 453561210231
Neo Analog Interface Module (NAIM) 453561210232
Neo Analog Interface Module (NAIM) 453561210233
Neo Analog Interface Module (NAIM) 453561210234
Neo Analog Interface Module (NAIM) 453561210235
Neo Analog Interface Module (NAIM) 453561210236
Analog Interface Module (AIM) 453561210241
Analog Interface Module (AIM) 453561210242
Analog Interface Module (AIM) 453561210243
Analog Interface Module (AIM) 453561210321
Analog Interface Module (AIM) 453561210322
Analog Interface Module (AIM) 453561210323
Rear Interface Panel (AVIO) 453561220671
Dual Signal Conditioning (DSC) 453561233802
Dual Signal Conditioning (DSC) 453561233803
FEC w/ 3D Motor Controller 453561236431
FEC w/ 3D Motor Controller 453561236432
FEC w/ 3D Motor Controller 453561236433
Unified Motherboard (UMB) 453561254492
SPD 453561264873
SPD 453561264874
Dual Signal Conditioning (DSC) 453561277001
Unified AVIO 453561278211
Unified AVIO 453561278212
Unified AVIO 453561278213
Front End Controller (FEC) 453561278261
Front End Controller (FEC) 453561278262
Front End Controller (FEC) 453561278263
Front End Controller (FEC) 453561278264
Front End Controller (FEC) 453561278265
Front End Controller (FEC) 453561278266
Front End Controller (FEC) 453561278267
Neo Analog Interface Module (NAIM) 453561279491
Neo Analog Interface Module (NAIM) 453561279492
Neo Analog Interface Module (NAIM) 453561279493
Neo Analog Interface Module (NAIM) 453561279494
Neo Analog Interface Module (NAIM) 453561279495
Neo Analog Interface Module (NAIM) 453561279496
Neo Analog Interface Module (NAIM) 453561279497
Neo Analog Interface Module (NAIM) 453561279498
Control & Display AVIO 453561280281
FEC w/ 3D Motor Controller 453561284571
FEC w/ 3D Motor Controller 453561284572
FEC w/ 3D Motor Controller 453561284573
Channel Board 453561287451
Channel Board 453561287452
Channel Board 453561303331
Channel Board 453561303332
Channel Board 453561303902
Unified AVIO 453561325292
Signal Processor Board (SPB) 453561343281
Unified Motherboard (UMB) 453561360251
Neo Analog Interface Module (NAIM) 453561454392
Front End Controller (FEC) 453561464291
Channel PCB 7500-1741
Dual Signal Conditioning (DSC) 7500-1898-02
Scanhead Select 7500-1933-02
Analog Interface Module (AIM) 7500-2017-01
Image Export Processor (IEP) 7500-2064-01
Rear Interface Panel (AVIO) 7500-2072-02
Control & Display (AVIO) 7500-2073-02

YOU MAY ALSO LIKE…

Maintaining and Troubleshooting the Philips iU22/iE33 Ultrasound Systems

The Philips iU22 and iE33 ultrasound systems are excellent general imaging, vascular and

cardiology units that have gained a very large share of the market over the last 10 years. There

are several maintenance tips and common problems that service providers should be aware of

on these systems.

Let's begin with how to prevent malfunctions and extended downtime. These systems can

be prone to overheating due to the air intakes being so close to the ground. Depending on the

environment (dusty, linen usage, etc.) the filters on the rear access panel and lower left side

Philips ultrasound machines user manual

panel should be cleaned quarterly or even more often to ensure adequate airflow to the power

supplies, acquisition and platform sections of the systems. There are also cooling vents inside

the rear wheel wells that should be vacuumed at the same intervals.

Also ensure current backups of the system's presets and option files are made. The

presets are backed up via the system setup menu but the option files are made through Tech

Admin. Having a proper backup is critical to mitigating downtime in the event of software

corruption or a hard drive failure.

Iu22 User Manual

One of the most common problems with these systems is related to video. The main

display communicates with the main computer (Host, UMB or EMB) and can show a partial

Terratech - to the stars pack download for mac download. display during the boot cycle but go blank upon system initialization. This is indicative of a bad

Philips Iu22 User Manual Pdf

main display despite it functioning during the boot cycle. Next, are the dual video cards

contained in the Platform (Back End). On A-C cart systems, the Host and SIP computers each

Philips Ie33 Ultrasound Machine Manual

contain a video card and on D-G cart systems, the UMB or EMB will have both. If video is

When plugged in turn off after. Turn off the display (plugged in) This policy setting allows you to specify the period of inactivity before Windows turns off the display.If you enable this policy setting you must provide a value in seconds indicating how much idle time should elapse before Windows turns off the display.If you disable or do not configure this policy setting users control this setting.If the user has configured a slide show to run on the lock screen when the machine is locked this can prevent the display. Screen setting 'When plugged in turn off after' turning off the screen at random times I trolled around here and did not find the exact problem I'm having with my Surface Pro 4 (today). A couple days ago I got to work and docked my Surface Pro 4 and started work. When enabled, your display will be turned off after your PC is idle for the configured period of time. The monitor screen will become black. The next time you access the device, the screen will show the desktop instantly. Also, it may be your lock screen image. Tip: see how to add Turn Off Display Context Menu in Windows 10. Sep 14, 2016 Power Settings in Windows 10: Instructions. To manage power settings in Windows 10, open the 'Settings' window. Then click the 'System' button in the middle of the screen. Then click the 'Power & sleep' category at the left side of this window. The power management and sleep options appear in the.

Toontown rewritten important tips for macro

panel should be cleaned quarterly or even more often to ensure adequate airflow to the power

supplies, acquisition and platform sections of the systems. There are also cooling vents inside

the rear wheel wells that should be vacuumed at the same intervals.

Also ensure current backups of the system's presets and option files are made. The

presets are backed up via the system setup menu but the option files are made through Tech

Admin. Having a proper backup is critical to mitigating downtime in the event of software

corruption or a hard drive failure.

Iu22 User Manual

One of the most common problems with these systems is related to video. The main

display communicates with the main computer (Host, UMB or EMB) and can show a partial

Terratech - to the stars pack download for mac download. display during the boot cycle but go blank upon system initialization. This is indicative of a bad

Philips Iu22 User Manual Pdf

main display despite it functioning during the boot cycle. Next, are the dual video cards

contained in the Platform (Back End). On A-C cart systems, the Host and SIP computers each

Philips Ie33 Ultrasound Machine Manual

contain a video card and on D-G cart systems, the UMB or EMB will have both. If video is

When plugged in turn off after. Turn off the display (plugged in) This policy setting allows you to specify the period of inactivity before Windows turns off the display.If you enable this policy setting you must provide a value in seconds indicating how much idle time should elapse before Windows turns off the display.If you disable or do not configure this policy setting users control this setting.If the user has configured a slide show to run on the lock screen when the machine is locked this can prevent the display. Screen setting 'When plugged in turn off after' turning off the screen at random times I trolled around here and did not find the exact problem I'm having with my Surface Pro 4 (today). A couple days ago I got to work and docked my Surface Pro 4 and started work. When enabled, your display will be turned off after your PC is idle for the configured period of time. The monitor screen will become black. The next time you access the device, the screen will show the desktop instantly. Also, it may be your lock screen image. Tip: see how to add Turn Off Display Context Menu in Windows 10. Sep 14, 2016 Power Settings in Windows 10: Instructions. To manage power settings in Windows 10, open the 'Settings' window. Then click the 'System' button in the middle of the screen. Then click the 'Power & sleep' category at the left side of this window. The power management and sleep options appear in the.

missing from the main display or touch panel(s), you can swap the video cards to see if the

symptoms change. There are several versions which are not interchangeable.

Iu22 User Manual Pdf

The ECG ports on these systems are part of the FEC board in the Acquisition section of

the system and the port can be damaged by the ECG cable to the patient area being stressed.

A cable tie attaching the main ECG cable to the system handle can prevent this.

One of the most unusual problems we have encountered is the intermittent or fixed issue

User Manual For A Website

of DICOM transmissions failing which we have found is due to a failure in the main power cord

ground.

These are some of the more common problems and we welcome complimentary technical

Ie33 Philips Manual

support requests at 866-900-9494.





broken image